AB-1850 LumiFL Spectrocapture > Luminescent Detector

본문 바로가기

쇼핑몰 검색

Home AB-1850 LumiFL Spectrocapture > Luminescent Detector
  • 제품소개 
  • 1D Gel Electrophoresis 2D Gel Electrophoresis Agarose Gel Electrophoresis Precast Gel Hand Gel Casting Power Supply Electrophoresis Reagents Western Blotting Blotting Reagents & Membranes Heat Block, Shaker Gel Documentation Luminescent Detector Luminescent Reagents Perista® Pump UV Monitor, Fraction Collector Reagents Live Cell Imaging

    AB-1850 LumiFL Spectrocapture > Luminescent Detector

    AB-1850 LumiFL Spectrocapture

    상품 상세설명

    Bio-Chemiluminescence Spectrophotometer

      AB-1850 is a highly sensitive spectrophotometer that can measure the spectrum of weak light, which was difficult to measure with existing spectrophotometers using photo diodes or PMT.

    AB-1850 LumiFL Spectrocapture

    AB-1850 LumiFL Spectrocapture

    Purpose and Application

    Investigation of molecular design of FRET(Fluorescence Resonance Energy Transfer)Investigation of molecular design of BRET(Bioluminescence Resonance Energy Transfer)development and quality control of luminescent/fluorescent reagents.Analysis of luminescent/fluorescent reactions.

    Features
    1. An electronic cooled CCD camera is used as a detector.
    2. A CCD is capable of receiving the light of the entire target wavelength region for measurement at one time and detecting it.
    3. A CCD has higher quantum efficiency than a photomultiplier tube.
    4. detection time is shortened with all wavelength simultaeous detection.
    5. Measurement waelength range is 400 to 800nm.
    6. Long-time exposure is available (high sensitive detection of micro specimens)
    7. When a fluorescent excitation light source is equipped, FRET or fluorescent substance can be measured.
    Specifications
    Product NumberAB-1850 
    Product NameLumiFLspectrocapture
    1.Luminescence and fluorescence test section
         F numberF3.0
         Measurement wavelength region400 - 800nm
         Reciprocal linear dispersion60nm/mm
         Wavelength resolution1.8nm
         Repeatability±0.6nm
         Slit width0.01mm - 5mm (11steps)
         Exposure time1/30second to60minutes(26steps)
         Light receiving sectionThermoelectric cooling CCD
    2.Spectroscope
         Number of diffraction gratings1 (standard)
         Diffraction grations150pcs/mm
         Blaze wavelength500nm
    3.Measurement sample
         Sample containerSquare quartz cell (10mmx10mm) /0.2mL PCR tube /35mm dish
         Sample volume10μL above
         Reagent injection parts for flush luminescenceAvailable
         Excitation lightFC connector for incident light is available(standard)
    4.Software
        FunctionControl measurement
         InterfaceUSB2.0
    5.Dimensions and weight
         PowerAC100V 50/60Hz 290VA
         Dimensions510mm(W)×725mm(D)×390mm(H)
         Weight 58kg 

     

    상품문의

    상품문의가 없습니다.

    상단